ABB RVT6 2GCA289004A0050
1. Product Overview
The ABB RVT power factor controller is a control unit for automatic switching of capacitor banks (or reactors), designed for reactive power compensation in on-site systems with inductive or capacitive loads. The RVT6 model enables precise power factor compensation for both balanced and unbalanced three-phase loads.
By automatically controlling the connection and disconnection of capacitors, the controller stabilizes the system power factor to reach the target cos φ value set by users.
2. Main Technical Parameters
|
Parameter Item
|
Specification
|
|
Product Model
|
RVT6-1/5A 2GCA289004A0050
|
|
Number of Output Channels
|
Up to 6 channels
|
|
Power Supply Voltage
|
100Vac to 460Vac
|
|
Frequency Range
|
45 Hz or 65 Hz (automatic adjustment)
|
|
Voltage Measurement Range
|
Up to 690Vac or measurable via voltage transformer
|
|
Current Input
|
5A or 1A RMS (Class 1 C.T.)
|
|
Power Consumption
|
Max. 15 VA
|
|
Operating Temperature
|
-20°C to 70°C
|
|
Ingress Protection Rating
|
Front panel IP43 (IP54 optional)
|
|
Overall Dimensions
|
146 x 211 x 67 mm
|
|
Cutout Dimensions
|
138 x 138 mm
|
|
Display Screen
|
QVGA 320 x 240 pixel color touch screen
|
2.1 Output Contact Rating
- Maximum continuous current: 1.5A (ac) / 0.3A (110V dc)
- Maximum peak current: 8A
- Maximum rated voltage: 440 Vac
- A-A terminal continuous rated current: 18A (9A per terminal)
2.2 Alarm Contact Rating
- 1 normally closed contact and 1 normally open contact
- Maximum continuous current: 1.5A (ac)
- Rated voltage: 250Vac (maximum breaking voltage: 440Vac)
3. Product Features
- Intelligent Control: Supports automatic commissioning, and automatic identification of CT connection, phase sequence, capacitor capacity and switching sequence.
- Diversified Switching Modes: Multiple switching modes available, including linear/cyclic, progressive/direct switching, standard/integral modes.
- Comprehensive Monitoring Functions: Displays real-time parameters and waveforms of voltage, current, harmonic, power, temperature and other operating data.
- Multi-layer Safety Protection: Adopts dual hardware and software locking design, with comprehensive protection and alarm records for undervoltage, overvoltage, harmonic interference and over temperature.
- Power Failure Protection: All capacitors will be automatically disconnected once power failure lasts more than 20 milliseconds.
- Expandable Communication: Compatible with Modbus RS485, USB 2.0, Ethernet TCP/IP and CAN 2.0 protocols.
- Multi-point Temperature Measurement: Supports up to 8 temperature probes with daisy-chain connection.
4. Structure and Composition
4.1 Appearance Structure
Adopts embedded installation design. The front panel is equipped with a touch screen and function mode buttons, while the rear panel is integrated with a complete terminal block for wiring.
4.2 Wiring Terminals
The integrated terminal block covers all functional interfaces:
- Power input (PS1/PS2)
- Voltage measurement input
- Neutral terminal
- CT connection terminal
- CAN bus interface
- Grounding terminal
- Temperature probe interface
- RS485 communication interface
- USB interface
- RJ45 Ethernet interface
- Relay output terminals
4.3 Output Terminal Configuration
- 1PhL1, 1PhL2, 1PhL3: Control single-phase compensation capacitors for L1, L2 and L3 phases respectively
- 3Ph: Controls three-phase integrated compensation capacitors
The RVT6 controller has three output statuses only: cut-off lock, switch-on lock and enable.
4.4 Installation Method
Embedded panel mounting, fixed with dedicated mounting brackets and screws.
5. Application Fields
- Automatic control of low-voltage reactive power compensation cabinets
- Three-phase power factor compensation for balanced and unbalanced loads
- Load compensation for residential and commercial districts (solving three-phase unbalance caused by widespread single-phase loads)
- Medium-voltage capacitor cabinet control (matched with voltage transformers)
- Power factor monitoring and optimization for industrial and commercial power distribution systems
- Automatic reactive power compensation control for power systems
6. Installation and Maintenance Instructions
6.1 Installation Steps
- Safety Preparation: All operations must be performed by qualified electricians with power completely cut off.
- Cutout Preparation: Reserve a panel cutout of 138 x 138 mm for installation.
- Fixation: Vertically slide the controller into the cabinet cutout and fasten it with mounting brackets.
- Wiring Requirements: Adopt 2.5 mm² single-core wires for wiring; install overcurrent protection (6A fuse recommended) at the power input terminal; remove the short-circuit piece of CT secondary winding after wiring is completed.
- Startup Configuration: Support one-click automatic commissioning (quick setup) and manual commissioning wizard for parameter configuration.
6.2 Maintenance Requirements
- Cleaning: Wipe the equipment with a dry cloth only. Do not use solvents, alcohol or other corrosive liquids for cleaning.
- Regular Inspection: Periodically check the stability of parameter settings and the firmness of wiring connections.
- Protection Reset: After protective actions (undervoltage, over temperature, etc.), restore the equipment operation in accordance with the specified delay time.
- Environmental Disposal: Compliant with WEEE and RoHS directives. The device shall be recycled and disposed of separately as electronic waste.

————————————————————————————————————-
If you would like to learn more about our products and services, please feel free to contact us at any time!
- Sales Manager : Jinny
- Email : sales5@xrjdcs.com
- Whatsapp/Mobile:+86 15359273791
Global renowned brand cooperation
ABB 丨 GE 丨Allen Bradley 丨 Honeywell 丨 Emerson 丨 Bently Nevada 丨 Westinghouse
Triconex 丨 Foxboro 丨 ICS Triplex 丨 Hima 丨 Schneider 丨 Yokogawa 丨 Woodward
—————————————————————————————

Cut Maintenance Costs – Optimize operations and reduce expenses with our high-quality, affordable automation replacement parts.
Always Available – Essential automation parts are constantly in stock, ensuring zero downtime for your operations.
24/7 Support – Our team is ready around the clock to assist with urgent needs and inquiries.
Fast Delivery – Ready stock enables quick dispatch and fast shipping, keeping your operations running smoothly.
100% Quality Assurance – Every part is strictly tested to ensure reliability and long-term performance.
Competitive Pricing & Outstanding Service – Exceptional service and unbeatable pricing maximize your value.
Choose us today for peace of mind, cost savings, and operational efficiency like never before!

Previous:
ABB SACO 64D-Ba SACO-16D2 Digital Alarm Unit
Next:
ABB PI774SIO Output Module