1. Overview
The GE 218A4293P6RB is a circuit breaker belonging to the GE 218 series, engineered for medium-voltage (5kV) power distribution networks. This series of circuit breakers stands out for its high reliability, straightforward operation, and easy maintenance, making it a critical protective device for industrial, commercial, and infrastructure power systems.
______________________________________________________________________________________________
2. Specifications
|
Parameter
|
Specification
|
|
Rated Voltage
|
5kV (Rated Operating Voltage)
|
|
Rated Current
|
170A (Marked by P6RB)
|
|
Number of Poles
|
2 Poles (Double Pole)
|
|
Insulation Type
|
Air-Bolted Insulation
|
|
Breaking Mode
|
Bolted Type (Mechanical disconnection via bolts)
|
|
Compliance Standard
|
IEC 60947-2
|
______________________________________________________________________________________________
3. Product Features
High Reliability: Adopts proven air-bolted insulation and bolted breaking technology, guaranteeing fast and effective circuit interruption under high fault current conditions.
Easy Maintenance: The bolted structural design simplifies on-site maintenance and component replacement (such as fuses), reducing downtime and labor costs.
Long Service Life: GE products are built with durable materials, delivering extended mechanical life and excellent weather resistance, suitable for long-term operation.
Strong Compatibility: Seamlessly integrates with other GE power distribution equipment, including relays and transformers, to form a complete and stable power distribution system.
______________________________________________________________________________________________
4. Structure and Components
Main Contact Assembly: Responsible for conducting and interrupting electrical current reliably.
Auxiliary Contacts (Optional): Used for signal indication or auxiliary circuit control.
Operating Mechanism: Consists of a handle, springs, and mechanical components, supporting both manual and electric operation.
Fuse Holder: Equipped in select variants to provide overload and overcurrent protection.
Enclosure: Offers robust mechanical protection and reliable electrical insulation for internal components.
______________________________________________________________________________________________
5. Applications
Industrial Power Distribution: Protects power distribution cabinets in factory workshops, warehouses, and other industrial facilities.
Commercial Buildings: Applied in main power distribution and branch circuits of shopping malls, office buildings, and other commercial premises.
Infrastructure: Safeguards power systems in critical infrastructure including airports, hospitals, and data centers.
Power Grid Distribution: Used as secondary equipment in substations and distribution stations.
______________________________________________________________________________________________
6. Installation and Maintenance
Installation
Mounting Location: Typically installed inside power distribution cabinets or boxes, with sufficient space reserved for heat dissipation.
Wiring: Follow IEC wiring standards to ensure correct phase sequence and secure, tight connections.
Mechanical Fixing: Secure the circuit breaker to the mounting base with bolts to prevent loosening during operation.
______________________________________________________________________________________________
Maintenance
Regular Inspection: Check the flexibility of the operating mechanism and inspect the handle for abnormal wear or damage.
Cleaning: Remove dust, corrosive substances, and debris from the enclosure regularly to maintain efficient heat dissipation.
Functional Testing: Perform regular opening tests to verify reliable circuit interruption under fault conditions.
Fuse Replacement: If equipped with a fuse holder, replace blown fuses promptly to restore normal protection function.