The ProSoft MVI69-PDPS is a compact Profibus DP (V0/V1) communication module designed for Rockwell Automation CompactLogix and ControlLogix PLC platforms. Learn about specs, features, and applications.
H2: 1. Overview
The ProSoft MVI69-PDPS is a compact I/O communication module with a modular design, specifically engineered for Rockwell Automation PLC platforms. It supports the Profibus DP (V0/V1) protocol, enabling reliable data exchange between the PLC and a wide range of field devices on the Profibus DP network, such as sensors, actuators, and other intelligent peripherals.
This module provides a seamless integration path for connecting Rockwell Automation controllers to existing Profibus DP installations, helping to protect your investment in legacy field devices while leveraging the power of modern PLC systems.
H2: 2. Specifications
- Model: MVI69-PDPS
- Communication Protocol: Profibus DP (V0 / V1)
- Form Factor: Single-slot module, compatible with Rockwell Automation 1769 CompactLogix and 1769 Modular I/O Chassis
- Power Supply: 5V DC, supplied by the PLC backplane
- Operating Temperature: -40°C to +70°C
- I/O Capacity: Up to 200 inputs and 200 outputs (actual I/O types and mapping depend on software configuration)
- Communication Cables: Includes an RJ45 to DB-9M cable and a 6-foot RS-232 cable for configuration and diagnostics
- Key Functions: Supports Freeze mode, Sync mode, and automatic baud rate detection
H2: 3. Key Features
-
Cross-Platform Compatibility
Works with multiple Rockwell Automation PLC platforms, including ControlLogix, CompactLogix, and MicroLogix, providing flexibility across your automation systems.
-
Simplified Network Configuration
Supports PROSOFT.fdt network configuration files, allowing for quick and consistent integration into your Profibus DP network using standard FDT/DTM tools.
-
Enhanced Diagnostics
Provides Extended Diagnostic Data to help maintenance and engineering personnel quickly identify and troubleshoot network issues, reducing downtime.
-
Flexible Stacking
Supports multi-module stacking to optimize rack space in compact control cabinets, ideal for applications with limited room.
-
Automatic Baud Rate Detection
Automatically detects the Profibus DP network baud rate, simplifying installation and commissioning and reducing setup time.
H2: 4. Module Structure and Components
-
Host Port
Connects to the PLC backplane, providing power and communication between the MVI69-PDPS and the controller.
-
Profibus DP Port
A standard 9-pin D-Sub connector for connecting to the Profibus DP bus, supporting both master and slave configurations depending on the application.
-
LED Indicators
Include module status, error conditions, and communication activity indicators, offering at-a-glance visibility of module and network health.
-
Internal Circuitry
Features a dedicated DSP for protocol handling and I/O data processing, ensuring fast and reliable communication performance.
H2: 5. Typical Applications
-
Industrial Automation
Serves as a key communication link between Rockwell Automation PLCs and a wide variety of field devices, including sensors, actuators, and drive systems.
-
Process Control
Ideal for use in oil and gas, chemical, pharmaceutical, and other process industries where reliable real-time data exchange is critical for safe and efficient operation.
-
Discrete Manufacturing
Widely used in automotive, packaging, food and beverage, and other discrete manufacturing environments to connect distributed I/O and intelligent devices.
H2: 6. Installation and Maintenance
-
Installation Preparation
Power off the PLC system before installing the MVI69-PDPS module. Insert the module into the designated slot in the Rockwell Automation 1769 chassis, ensuring it is fully seated and locked in place.
-
Wiring
Use shielded twisted-pair cable compliant with Profibus DP standards to connect the module’s 9-pin D-Sub port to the Profibus DP network. Proper shielding and grounding are essential for reliable communication.
-
Termination Resistors
Install and configure termination resistors at both ends of the Profibus DP bus in accordance with your network topology to prevent signal reflections.
-
Parameter Configuration
Configure module parameters, such as baud rate and node address, using Rockwell Automation programming software such as RSLogix 5000 or Studio 5000.
-
Maintenance Recommendations
The MVI69-PDPS typically requires minimal maintenance. Periodically inspect network connections, monitor LED status, and keep the module firmware up to date to ensure compatibility with the latest devices and software versions.

————————————————————————————————————-
If you would like to learn more about our products and services, please feel free to contact us at any time!
- Sales Manager : Jinny
- Email : sales5@xrjdcs.com
- Whatsapp/Mobile:+86 15359273791
Global renowned brand cooperation
ABB 丨 GE 丨Allen Bradley 丨 Honeywell 丨 Emerson 丨 Bently Nevada 丨 Westinghouse
Triconex 丨 Foxboro 丨 ICS Triplex 丨 Hima 丨 Schneider 丨 Yokogawa 丨 Woodward
—————————————————————————————

Strengths
-
Extensive InventoryWe offer a wide range of industrial automation components, including PLCs, DCS systems, HMIs, and power supplies, ensuring a diverse product selection for various industries.
-
Global ReachWith an international customer base, we provide reliable cross‑continental shipping and services to clients worldwide.
-
Competitive PricingBy sourcing high‑quality products at competitive prices, we deliver cost‑effective solutions that help businesses reduce operational expenses.
-
Hard‑to‑Find PartsWe specialize in sourcing obsolete or discontinued components, making us a preferred supplier for rare industrial parts.
-
Fast DeliveryWe ensure quick shipping options to minimize downtime for businesses needing urgent replacements or upgrades.
Q: What is your expertise?A: We specialize in providing industrial automation components, including spare parts for PLCs, DCS systems, HMIs, power supplies, and other industrial equipment.
Q: Can you source obsolete or hard‑to‑find parts?A: Yes, Xingruijia is known for sourcing discontinued or rare components that are difficult to find elsewhere.
Q: Do you offer international shipping?A: Yes, we provide global shipping services to ensure customers around the world can access our products.
Q: How do you ensure product quality?A: We perform strict quality assurance checks on all products to ensure they meet industry standards and operate reliably in demanding environments.
Previous:
PROSOFT MVI56-MBP Dual-Port Communication Module
Next:
PROSOFT Prosoft FMVI94 MCM Network Interface Module