The PM8500 is a multi-channel electrical parameter measuring instrument under XYCOM, specifically designed for real-time monitoring of power quality parameters such as power, power factor, and harmonics. Equipped with an LED digital display, all measurements are True RMS (Trms), featuring high anti-interference capability and data hold function. It is suitable for various scenarios including laboratories, production lines, and on-site testing.
Key Technical Specifications
- Display Mode: LED digital screen, capable of showing voltage, current, power, power factor, frequency, energy, and 1–50th harmonics
- Alarm Function: Upper and lower threshold settings for current and power to trigger alarms
- Measurement Method: True RMS (Trms) measurement with high noise immunity
- Range Switching: Supports multi-range switching to meet different power level requirements
- Data Hold: Locks key measurement data to prevent misoperation
- Dimensions/Weight: Approximately 20.7 × 11.4 × 6.9 cm, weighing about 360 g
Product Features
- Multi-parameter Synchronous Display: Simultaneously shows voltage, current, power, power factor, frequency, energy, and harmonics in one measurement for comprehensive power quality evaluation.
- Threshold Alarm: Users can set custom upper and lower limits for current and power; the instrument triggers automatic alarms when exceeding limits, ideal for safety monitoring.
- High Anti-interference: Adopts anti-noise design with strong immunity to external electromagnetic interference, ensuring measurement accuracy.
- Data Hold and Storage: Locks and exports key measurement values for later analysis and report preparation.
- Modular Range Switching: Easy range adjustment to adapt to testing needs of different power ranges.
Structure and Composition
- Main Unit: Built-in LED display, control keyboard, and measurement circuit board.
- Input Terminals: Multiple voltage/current inputs, supporting three-phase or single-phase connection.
- Communication Interfaces: Industrial standard interfaces such as RS-485 and Ethernet (10/100 Mbps) for remote monitoring and data acquisition.
- Power Module: 24 V DC power supply with an operating voltage range of 18–30 V and overvoltage protection.
- Enclosure: Complies with IP65 protection rating, suitable for harsh industrial environments.
Typical Application Fields
- Power consumption testing of household appliances (e.g., air conditioners, lighting, LED lamps)
- Power consumption and efficiency evaluation of motors and engines
- Power and energy efficiency testing of chargers and switching power supplies
- Specialized measurement for Automated Test Equipment (ATE) systems
- Power quality monitoring and fault diagnosis in industrial sites
Installation and Maintenance Guidelines
Installation
- Adopts modular plug-and-play design; confirm the wiring sequence of power supply, signal lines, and communication lines before plugging in.
- Supports hot swapping; no need to power off when replacing or upgrading modules, reducing downtime.
- Fix the instrument in a cabinet or panel with IP65 protection rating to ensure dust and water resistance.
Commissioning
- Perform self-inspection after power-on to confirm the normal operation of the display, keyboard, and communication interfaces.
- Conduct zero calibration and full-scale calibration for input channels using the instrument’s built-in calibration function.
- Set the required range, alarm thresholds, and communication parameters (baud rate, station number, etc.), and conduct joint debugging with upper computer software.
Daily Maintenance
- Regularly check the tightness of input terminals and communication interfaces to avoid measurement errors caused by looseness.
- Perform internal cleaning every six months, especially for heat sinks and fans (if equipped), to maintain smooth heat dissipation.
- Record the time, items, and replaced components of each maintenance for traceability.
Troubleshooting
- If abnormal alarms or display errors occur, first check if the power supply voltage is within the 18–30 V range.
- Use the instrument’s built-in self-inspection function to locate faulty modules; replace the corresponding measurement card or communication module if necessary.
- For software-related communication abnormalities, troubleshoot by reconfiguring RS-485/Ethernet parameters or replacing network cables.
————————————————————————————————————-
If you would like to learn more about our products and services, please feel free to contact us at any time!
- Sales Manager : Jinny
- Email : sales5@xrjdcs.com
- Whatsapp/Mobile:+86 15359273791
Global renowned brand cooperation
ABB 丨 GE 丨Allen Bradley 丨 Honeywell 丨 Emerson 丨 Bently Nevada 丨 Westinghouse
Triconex 丨 Foxboro 丨 ICS Triplex 丨 Hima 丨 Schneider 丨 Yokogawa 丨 Woodward
—————————————————————————————

Our Advantages
100% Brand New & Original Products
→ 12-Month Warranty
→ High Quality
→ Competitive PricingProfessional
After-Sales Service
Adequate SupplyWe offer a wide range of products.
In-stock availability: Bulk orders are ready for immediate fulfillment.Contact us for more details!
Why Choose Us?
- Competitive pricing
- 12-month warranty
- Professional services
- Guaranteed brand new and genuine products
- On-time delivery

Previous:
XYCOM 82034CA Industrial Control Board
Next:
Eaton URTDII-02 Resistance Temperature Detector (RTD) Module